Byggnadsmaterial och byggnader

Ämnesområden: Byggförnödenheter
Kommittébeteckning: SIS/TK 615 (Lås och beslag)
Källa: CEN
Svarsdatum: den 30 jun 2026
Se merSe mindre
 

This document specifies product characteristics and test methods of mechanically operated locks and their locking plates. This document covers mechanically operated locks and their locking plates which are either manufactured and placed on the market in their entirety by one producer or assembled from sub-assemblies produced by more than one producer and designed to be used in combination. This document does not cover assessment of the contribution of the product to the fire resistance of specific fire resistance and/or smoke control door set assemblies. This document is not applicable to mechanically/electromechanically cylinders, handles, locks for windows, padlocks, locks for safes, furniture locks or prison locks. This document does not specify mechanically operated multipoint locks and their locking plates which are specified by EN 15685.

Ämnesområden: Byggförnödenheter
Kommittébeteckning: SIS/TK 615 (Lås och beslag)
Källa: CEN
Svarsdatum: den 30 jun 2026
Se merSe mindre
 

This document specifies product characteristics and test methods of mechanically operated multipoint locks and their locking plates. This document covers multipoint locks their locking plates which are either manufactured and placed on the market in their entirety by one producer or assembled from sub-assemblies produced by more than one producer and designed to be used in combination. This document does not cover assessment of the contribution of the product to the fire resistance of specific fire resistance and/or smoke control door set assemblies. This document is not applicable to mechanically/electromechanically cylinders, handles, locks for windows, padlocks, locks for safes, furniture locks or prison locks. This document does not specify mechanically operated locks or their locking plates which are specified by EN 12209.

Ämnesområden: Vattenvärmare
Kommittébeteckning: SIS/TK 198/AG 02 (Vattenförsörjning)
Källa: CEN
Svarsdatum: den 1 jul 2026
Se merSe mindre
 

This document specifies the general specifications, constructional requirements and common test methods for indirectly heated, unvented (closed) hot water storage tanks of up to 2 000 l volume suitable for connection to a water supply at a pressure between 0,05 MPa and 1,0 MPa (0,5 bar and 10 bar), and fitted with control and safety devices designed to prevent the temperature of the stored drinking water from reaching 95 °C. Whilst storage water heaters intended primarily for direct heating are not covered by this document, it includes the possible provision of backup immersion heaters.

Ämnesområden: Gasinstallationer
Kommittébeteckning: SIS/TK 289 (Gassystem)
Källa: CEN
Svarsdatum: den 7 jul 2026
Se merSe mindre
 

This document specifies requirements and tests for the construction, performance, safety and production of battery powered class 1,5 Capillary Thermal-Mass Flow sensor gas meters (hereinafter referred to as meter(s)). This applies to meters having co-axial single pipe, or two pipe connections, which are used to measure volumes of fuel gases of the 2nd and/or 3rd family, as given in EN 437:2021.

In general, the term “thermal mass flow meters” applies to a flow-measuring device using heat transfer to measure and indicate gas flowrate, as defined in ISO 14511.

NOTE Although the word “mass” is present in the definition of the measurement principle, gas meters covered by this document provide measurement of gas at base conditions of temperature and pressure.

These meters have a maximum working pressure not exceeding 0,5 bar and a maximum flowrate not exceeding 160 m3/h over a minimum ambient temperature range of −10 °C to +40 °C and a gas temperature range as specified in the marking, with a minimum range of 40 °C.

For meters designed for hydrogen measurement, the maximum flowrate is not exceeding 480 m3/h, whilst the other characteristics are as stated above.

This document applies to meters indicating volume at base conditions, which are installed in locations with vibration and shocks of low significance. It applies to meters in:

— closed locations (indoor or outdoor with protection, as specified in the instruction manual) with condensing humidity or with non-condensing humidity;

or, if specified in the marking:

— open locations (outdoor without any covering) both with condensing humidity or with non-condensing humidity;

and in locations with electromagnetic disturbances likely to be found in residential, commercial and light industrial use. For meters which indicate unconverted volume, reference can be made to Annex C.

Unless otherwise stated, all pressures given in this document are gauge pressures.

Requirements for electronic indexes, valves and additional requirements for batteries incorporated in the meter and any other additional functionalities are given in EN 16314:2013.

Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices, as indicated in the instruction manual.

Clauses 1 to 13 are for design and type testing only.

For meters designed for blended gas and/or hydrogen measurement, refer to Annex E.

This document refers only to hydrogen as specified in ISO 14687:2025 with a purity of type I grade A or better.

Unless otherwise stated, all tests applicable to 2nd and 3rd family gases are applicable also to blended gas and hydrogen.

Mixtures with a hydrogen concentration above 20 % and below 98 % by volume are not covered by this document.