This document specifies the requirements for the attachment of multi-turn actuators to valves.
Throughout this document, “actuator” can be understood as “actuator and/or gearbox” providing a multi-turn and/or linear output.
It specifies:
— flange dimensions necessary for the attachment of actuators to industrial valves [see Figure 1 a)] or to intermediate supports [see Figure 1 b)];
— those driving component dimensions of actuators which are necessary to attach them to the driven components;
— reference values for torque and thrust for flanges having the dimensions specified in this document.
This document specifies requirements for the attachment of part-turn actuators, with or without gearboxes, to industrial valves.
The attachment of part-turn actuators to control valves in accordance with the requirements of this document is subject to an agreement between the supplier and the purchaser.
This document specifies:
— flange dimensions necessary for the attachment of part-turn actuators to industrial valves [see Figures 1 a) and 1 c)] or to intermediate supports [see Figures 1 b) and 1 d)];
— driving component dimensions of part-turn actuators necessary to attach them to the driven components;
— reference values for torques for interfaces and for couplings having the dimensions specified in this document.
The attachment of the intermediate support to the valve is out of the scope of this document.
This document specifies a methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods.
This methodology is also intended to be used outside premises for all potable water systems connected to a potable water distribution system up to and including the point of use.
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. In the absence of a product standard, this document is intended to be used as a reference to draw up a specification for the development of new devices or arrangements.