Bullermätning och bullerbekämpning: allmänt

Kommittébeteckning: SIS/TK 110 (Akustik och buller)
Källa: ISO
Svarsdatum: den 6 feb 2023
Se merSe mindre
 

This document specifies an engineering method for calculating the attenuation of sound during propagation outdoors in order to predict the levels of environmental noise at a distance from a variety of sources. The method predicts the equivalent continuous A-weighted sound pressure level (as described in Parts 1 to 2 of ISO 1996) under meteorological conditions favourable to propagation from sources of known sound emission.
These conditions are for downwind propagation or, equivalently, propagation under a well-developed moderate ground‑based temperature inversion, such as commonly occurs in clear, calm nights.
Inversion conditions over extended water surfaces are not covered and may result in higher sound pressure levels than predicted from this document (see e.g[5]. and[6]).
The method also predicts a long-term average A‑weighted sound pressure level as specified in ISO 1996-1 and ISO 1996-2. The long-term average A‑weighted sound pressure level encompasses levels for a wide variety of meteorological conditions.
Guidance has been provided to derive a meteorological correction based on the angular wind distribution relevant for the reference or long-term time interval as specified in 3.2.1 and 3.2.2 of ISO 1996-1:2016. Examples for reference time intervals are day, night or the hour of the night with the
largest value of the sound pressure level. Long-term time intervals over which the sound of a series of reference time intervals is averaged or assessed representing a significant fraction of a year (e. g.
3 months, 6 months or 1 year).
The method specified in this document consists specifically of octave-band algorithms (with nominal mid-band frequencies from 63 Hz to 8 kHz) for calculating the attenuation of sound which originates from a point sound source, or an assembly of point sources. The source (or sources) may be moving or stationary. Specific terms are provided in the algorithms for the following physical effects:
— geometrical divergence;
— atmospheric absorption;
— ground effect;
— reflection from surfaces;
— screening by obstacles.
Additional information concerning propagation through foliage, industrial sites and housing is given in Annex A. The directivity of chimney-stacks to support the sound predictions for industrial sites has been included with Annex B. An example how the far-distance meteorological correction C0 can be determined from the local wind-climatology is given in Annex C. Experience of the last decade how to predict the sound pressure levels caused by wind turbines is summarized in Annex D.
The method is applicable in practice to a great variety of noise sources and environments. lt is applicable, directly or indirectly, to most situations concerning road or rail traffic, industrial noise sources, construction activities, and many other ground-based noise sources. It does not apply to sound
from aircraft in flight, or to blast waves from mining, military or similar operations.

To apply the method of this document, several parameters need to be known with respect to the
geometry of the source and of the environment, the ground surface characteristics, and the source
strength in terms of octave-band sound power levels for directions relevant to the propagation.
lf only A‑weighted sound power levels of the sources are known, the attenuation terms for 500 Hz may
be used to estimate the resulting attenuation.
The accuracy of the method and the limitations to its use in practice are described in Clause 9.

Kommittébeteckning: SIS/TK 110 (Akustik och buller)
Källa: CEN
Svarsdatum: den 16 mar 2023
Se merSe mindre
 

This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements.
NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method, or a noise
test code that refers to this method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface.

Kommittébeteckning: SIS/TK 110 (Akustik och buller)
Källa: CEN
Svarsdatum: den 16 mar 2023
Se merSe mindre
 

This document gives guidance on the determination of (measurement) uncertainties of sound power levels determined according to ISO 3741, ISO 3743-1, ISO 3743-2, ISO 3744, ISO 3745, ISO 3746 and ISO 3747.