Detaljer om förslaget
This document specifies the minimum requirements for the material, design construction and workmanship, manufacturing processes, examination and testing at time of manufacture of an assembly of permanently mounted composite tube(s) in a frame with associated components.
Tubes covered by the requirements of this document are:
a) of composite construction, permanently mounted in a transport frame and suitable for specified service conditions, designated as:
Type 3 — a fully wrapped tube with a seamless metallic liner and composite reinforcement on both the cylindrical part and the dome ends; or
Type 4 — a fully wrapped tube with a non-load sharing liner and composite reinforcement on both the cylindrical part and the dome ends.
b) with water capacities from 450 l up to and including 10 000 l;
c) containing compressed gases but excluding:
liquefied gases,
dissolved gases, and
gases and gas mixtures which are classified for transport as toxic or oxidizing;
d) with working pressure up to 1 000 bar.
This document does not address tubes with working pressure times water capacity (p × V) more than 3 000 000 bar∙l.
Detta dokument föreslås att fastställas och publiceras som svensk standard.
För att lämna allmänna kommentarer på standardförslaget i sin helhet och på föreslagen titel – klicka på förslagets titel.
För att lämna specifika kommentarer på innehållet – skriv kommentaren och föreslagen ändring i rutan under avsnittet i fråga.
Standardförslag på engelska föreslås att fastställas som svensk standard utan översättning. Kommentarer på engelskspråkiga standardförslag bör vara på engelska.
För att ett standardförslag ska kunna fastställas som svensk standard måste det vara förenligt med svensk lagstiftning. Det är således viktigt att berörda svenska myndigheter klarlägger ifall standardförslaget är förenligt med svensk lagstiftning.