This document contains requirements for the design, testing, inspection and marking of serially produced, refillable storage systems intended only for liquid hydrogen for land vehicle operation. These storage systems
a) are permanently attached to the vehicle,
b) are vacuum insulated,
c) have a hydrogen pressure retaining structure and vacuum enclosure consisting of metallic materials.
The scope of this document is limited to fuel storage systems containing fuel cell grade hydrogen according to ISO 14687 type II grade D. The content is mainly focused on heavy duty vehicles for road operation but may also be applied to on-board fuel storage systems for other road vehicles, industrial and other land vehicles with due consideration of appropriate service conditions.
Detta dokument föreslås att fastställas och publiceras som svensk standard.
För att lämna allmänna kommentarer på standardförslaget i sin helhet och på föreslagen titel – klicka på förslagets titel.
För att lämna specifika kommentarer på innehållet – skriv kommentaren och föreslagen ändring i rutan under avsnittet i fråga.
Standardförslag på engelska föreslås att fastställas som svensk standard utan översättning. Kommentarer på engelskspråkiga standardförslag bör vara på engelska.
För att ett standardförslag ska kunna fastställas som svensk standard måste det vara förenligt med svensk lagstiftning. Det är således viktigt att berörda svenska myndigheter klarlägger ifall standardförslaget är förenligt med svensk lagstiftning.