Detaljer om förslaget

Svensk titel: Explosiv atmosfär – Förbränningsmotorer (ISO/IEC DIS 80079-41:2025)
Nummer:prEN ISO/IEC 80079-41
Källa:CEN
Kommitté:SIS/TK 001
Namn på kommittén:SIS/SEK ATEX
Publicerat:den 4 apr 2025
Sista svarsdatum:den 3 jun 2025
Contact email:kommentera(at)sis.se
Förslagets omfattning:

This part of ISO/IEC 80079 specifies the technical requirements for design, construction, conversion, testing, marking and the information required for use to avoid or minimise the possibility of ignition which could from reciprocating internal combustion engine intended for use in explosive atmospheres including:

– Group I EPL Mb for use in underground workings susceptible to firedamp or combustible dust,

– Group II EPL Gb and EPL Gc for use in explosive atmospheres of flammable gas and vapour, and

– Group III EPL Db and EPL Dc for use in explosive atmospheres of combustible dust.

– For EPL Gc and Dc engines, only normal operating conditions need to be taken into account. Malfunctions need not be considered (see B.2.1).

This document includes those tests of the engine and its ancillary devices that are required to verify compliance with this document. This document applies to both reciprocating internal combustion engines with compression ignition for EPL Mb, Gb, Gc, Db, Dc and gaseous fuelled spark ignition engines for EPL Gc. See Annex G.

This document does not define requirements relating to the driven machinery and equipment. This document does not apply to – explosive mixtures of vapours and gases, which tend to self-decompose (for example carbon disulphide (CS2), ethylene oxide (C2H4O), acetylene (C2H2)) or which are chemically unstable;

• hydrogen fueled engines, including blends;

• engines used in areas for the processing, manufacture or storage of explosives;

• gasoline and other spark ignited engines where the fuel is injected into the combustion chamber as a liquid; or

• electrical ignition spark systems.

Note 1 Spark ignition systems used with equipment covered by ISO/IEC 80079-41 is covered by IEC 60079-45

This document solely deals with explosion protection requirements. Requirements on gaseous or particulate exhaust emissions are not covered by this standard.

General safety requirements are not included in this International Standard.

NOTE 1 General safety requirements are covered for the EU in EN 1679-1:1998+A1:2011.

This document does not specify requirements for safety, other than those directly related to the possibility of ignition of flammable mixtures in the surrounding atmosphere which can lead to an explosion. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it can be assumed that the engine may be operated are:

• temperature –20 °C to +60 °C

• pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and

• air with normal oxygen content, typically 21% v/v.

An engine for use outside of the standard atmospheric conditions is to be designed, constructed tested and marked for those conditions. The ignition hazard assessment, ignition, protection provided, additional testing (if necessary) manufacturer’s technical documentation and instructions to the user are intended toclearly demonstrate the engine’s suitability for the conditions.

NOTE 2 changes in temperature and pressure have an influence on the characteristics of the explosive atmosphere including ignitability

NOTE 3 IEC TS 60079-43 gives information for equipment used in explosive atmospheres in environmental conditions which include ambient temperatures below –20 °C and additional adverse conditions, including maritime applications.

NOTE 4 Reciprocating internal combustion engines are not considered as pressure vessels. This document supplements and modifies the general requirements of IEC 60079-0:2017 and ISO 80079-36. Where a requirement of this document conflicts with a requirement of IEC 60079-0:2017 and ISO 80079-36 as far as applicable for Ex engines, the requirement of this standard takes precedence.

NOTE 5 On-going inspection, maintenance and repair aspects play an important role in control of hazardous area installations and the user’s attention is drawn to IEC 60079-17, IEC 60079-19 and IEC 60079-14 and manufacturer’s instructions for further information concerning these aspects.

Detta dokument föreslås att fastställas och publiceras som svensk standard.

För att lämna allmänna kommentarer på standardförslaget i sin helhet och på föreslagen titel – klicka på förslagets titel.

För att lämna specifika kommentarer på innehållet – skriv kommentaren och föreslagen ändring i rutan under avsnittet i fråga.

Standardförslag på engelska föreslås att fastställas som svensk standard utan översättning. Kommentarer på engelskspråkiga standardförslag bör vara på engelska.

För att ett standardförslag ska kunna fastställas som svensk standard måste det vara förenligt med svensk lagstiftning. Det är således viktigt att berörda svenska myndigheter klarlägger ifall standardförslaget är förenligt med svensk lagstiftning.